Twin Datalink Cable
Application
The cables are used as interconnecting cables for Solid State Interlocking (SSI) systems.
Standards
- BR 1932
Construction
- Conductors: Class 1 solid plain copper conductor, 1.27mm nominal diameter.
- Insulation: Solid polyethylene.
- Inner Sheath: Low density polyethylene.
- Moisture Barrier: PE Copolymer coated aluminium tape.
- Sheath: Low density polyethylene.
- Core Identifi cation: Blue & Red.
Electrical Characteristics at 20℃
Nominal Conductor Diameter | mm | 1.27 |
Nominal Conductor Cross Section | mm² | 2.5 |
Maximum Conductor Resistance | Ω/km | 7.41 |
Mechanical and Thermal Properties
- Minimum Bending Radius: 6×OD
- Temperature Range: -25℃ to +85℃ (during operation); -10℃ to +85℃ (during installation)
Dimensions and Weight
Cable Code | No. of pairs | Nominal Sheath Thickness mm |
Overall Diameter Min/Max mm |
Nominal Weight kg/km |
1.27mm Conductor, 2.59mm Insulation Wire | ||||
RS1932-2Y2Y(L)2Y-1P1.27 | 1 | 2.5 | 12.47/12.8 | 136 |