RT/F3 D & S & B type Axle Counter Cable
Application
The cables are designed for transmission of signals up to 90 kHz in axle counter train detection systems.
Standards
- RT/E/PS/00031
Construction
- Conductors: Tinned copper, 0.9/1.4 mm nominal diameter.
- Insulation: Solid polyethylene.
- Cabling Element: Two insulated conductors are twisted together to form a pair.
- Stranding: Pairs are helically stranded in concentric layers.
- Filling: Cable core interstices are filled with a low-permitivity compound. Unfi lled cables option can be offered upon request.
- Core Wrapping: Plastic tape(s) with overlapping.
- Moisture Barrier: One laminated sheath made of aluminium tape coated with PE Copolymer on at least one side is applied with longitudinally overlap.
- Inner Sheath (for S/B type): Polyethylene or LSZH fi re retardant compound.
- Mechanical Protection (for S/B type): One corrugated steel tape or brass tape is longitudinally applied with overlap. Unarmoured cables option can be offered upon request.
- Outer Sheath: Polyethylene or LSZH fi re retardant compound. Ruggedised PE sheath compound can be offered upon request.
Type Codes
- F1 class: Non LSZH cables.
- F5 class: Unfi lled cables
- D type: Unarmoured types
- R type: Ruggedised PE sheath
- S type: Steel tape armoured types
- B type: Brass tape armoured types
- E1, E2 & E3 types: 3 different induction protection levels available.
Electrical Characteristics at 20℃
Nominal Conductor Diameter | mm | 0.9 | 1.4 |
Nominal Conductor Cross Section | mm² | 0.63 | 1.5 |
Maximum Conductor Resistance | Ω/km | 30.0 | 12.5 |
Minimum Insulation Resistance @500 V DC (1min) | MΩ.km | 5000 | 5000 |
Nominal Conductor Capacitance @800Hz/1000Hz (AC) | nF/km | 42+3 | 47+3 |
Dielectric Strength, conductor to screen (DC voltage 2mins) | V | 3000 | 3000 |
Maximum Average Attenuation | |||
@1.0KHz | dB/km | 0.73 | 0.45 |
@2.4KHz | dB/km | 1.10 | 0.62 |
@40KHz | dB/km | 2.88 | 1.77 |
@90KHz | dB/km | 3.70 | 2.41 |
@1.024MHz | dB/km | 11.2 | 7.45 |
Minimum Average Near-end Crosstalk | |||
@1.0KHz | dB/km | 60 | 60 |
@2.4KHz | dB/km | 60 | 60 |
@40KHz | dB/km | 50 | 50 |
@90KHz | dB/km | 50 | 50 |
@1.024MHz | dB/km | 35 | 35 |
Mechanical and Thermal Properties
- Minimum Bending Radius: 7.5×OD (unarmoured); 10×OD (armoured)
- Temperature Range: -30℃ to +60℃ (during operation); -10℃ to +60℃ (during installation)
Core Identification
Dimensions and Weight
A-2Y(F)(L)2Y n×2×0.9/1.4 Cables
Cable Code | Number of Pairs (n) |
Nominal Sheath Thickness mm |
Maximum Overall Diameter mm |
Nominal Weight kg/km |
0.9mm Conductor, 1.55mm Insulated Wire | ||||
RS/RT/F3-D-2Y(F)(L)2Y-2P0.9 | 2 | 2.4 | 13.2 | 210 |
RS/RT/F3-D-2Y(F)(L)2Y-10P0.9 | 10 | 2.4 | 21.6 | 530 |
RS/RT/F3-D-2Y(F)(L)2Y-12P0.9 | 12 | 2.4 | 24.8 | 580 |
RS/RT/F3-D-2Y(F)(L)2Y-19P0.9 | 19 | 2.4 | 31.2 | 800 |
RS/RT/F3-D-2Y(F)(L)2Y-24P0.9 | 24 | 2.4 | 33.8 | 980 |
1.4mm Conductor, 2.2mm Insulated Wire | ||||
RS/RT/F3-D-2Y(F)(L)2Y-2P1.4 | 2 | 2.4 | 23.4 | 320 |
RS/RT/F3-D-2Y(F)(L)2Y-10P1.4 | 10 | 2.4 | 30.0 | 910 |
RS/RT/F3-D-2Y(F)(L)2Y-12P1.4 | 12 | 2.4 | 32.0 | 1101 |
RS/RT/F3-D-2Y(F)(L)2Y-19P1.4 | 19 | 2.4 | 37.3 | 1450 |
RS/RT/F3-D-2Y(F)(L)2Y-24P1.4 | 24 | 2.4 | 42.3 | 1780 |
A-2Y(L)2YB2Y n×2×0.9/1.4 Cables
Cable Code | Number of Pairs (n) |
Nominal Sheath Thickness mm |
Maximum Overall Diameter mm |
Nominal Weight kg/km |
|
0.9mm Conductor, 1.8mm Insulated Wire | |||||
RS/RT/F3-S-2Y(L)2YB2Y-2P0.9 | 2 | 2.2 | 2.4 | 22.0 | 399 |
RS/RT/F3-S-2Y(L)2YB2Y-10P0.9 | 10 | 2.2 | 2.4 | 30.4 | 880 |
RS/RT/F3-S-2Y(L)2YB2Y-12P0.9 | 12 | 2.2 | 2.4 | 33.6 | 963 |
RS/RT/F3-S-2Y(L)2YB2Y-19P0.9 | 19 | 2.2 | 2.4 | 40.0 | 1312 |
RS/RT/F3-S-2Y(L)2YB2Y-24P0.9 | 24 | 2.2 | 2.4 | 42.6 | 1626 |
1.4mm Conductor , 2.7mm Insulated Wire | |||||
RS/RT/F3-S-2Y(L)2YB2Y-2P1.4 | 2 | 2.2 | 2.4 | 32.2 | 608 |
RS/RT/F3-S-2Y(L)2YB2Y-10P1.4 | 10 | 2.2 | 2.4 | 38.8 | 1510 |
RS/RT/F3-S-2Y(L)2YB2Y-12P1.4 | 12 | 2.2 | 2.4 | 40.8 | 1827 |
RS/RT/F3-S-2Y(L)2YB2Y-19P1.4 | 19 | 2.2 | 2.4 | 46.1 | 2380 |
RS/RT/F3-S-2Y(L)2YB2Y-24P1.4 | 24 | 2.2 | 2.4 | 51.1 | 2954 |