Signalling & Control Cable to Spain RENFE Rail Standard
EAPSP
EAPSP are multicore and multiquad signalling cables without induction protection, which can be installed directly to the ground. This is equivalent to A-2Y(L)2Y(SR)2Y according to VDE standard. The cables are equipped with moisture barrier and corrugated steel tape armouring.
CCPSSP & CCTSST
CCPSSP & CCTSST are multicore, multipair or multiquad armoured signalling cables used for transmission of low frequency signals in high speed lines. Either copper wires or tapes are used to serve as electrostatic shield. With the combination of either copper tapes or wires and double layers of 0.8mm thick steel tape, the cables can offer either 0.1 (copper wire) or 0.3 (copper tape) reduction factor. CCPSSP is covered with PE sheath equivalent to AJ-2Y(St)2YB2Y according to VDE standard and CCTSST is covered with fi re retardant non corrosive PE sheath, similar to AJ-2Y(St) HBH. The cables can be jelly fi lled to offer full watertightness.